8.8. R46 Limit switch manual input

8.8. R46 Limit switch manual input

 

Starts pulse counting by compulsorily inputting limit switch operation signal from teaching pendant irrespective of operation of actual limit switch.

 

(1)   When you press the [R..(NO)] key → [46] → [ENTER(YES)] key, the limit switch forced input selection window will be displayed.

 

(2)   If pressing the [ENTER (YES)] key, the limit switch is compulsorily input so as to start pulse counting or enter into multiple of works. This function is cancelled if pressing the [R..(NO)] key.

 

 

 

l  This function cannot be executed in AUTO mode. Always use it in Manual mode.

 

l  This is a function that will operate only when set to Simulation Test or Test in [F2]: System4: Application parameter4: Sensor synchronization2: Environment settingSensor activation = <Normal, Simulation, Test>