8.8. R46 Limit switch manual input

8.8. R46 Limit switch manual input​

 

Starts pulse counting by compulsorily inputting limit switch operation signal from teaching pendant irrespective of operation of actual limit switch.

 

(1)   When you press the [R..(NO)] key → [46] → [ENTER(YES)] key, the limit switch forced input selection window will be displayed.

 

(2)   If pressing the [ENTER (YES)] key, the limit switch is compulsorily input so as to start pulse counting or enter into multiple of works. This function is cancelled if pressing the [R..(NO)] key.

 

 

 

l  This function cannot be executed in AUTO mode. Always use it in Manual mode.

 

l  This is a function that will operate only when set to Simulation Test or Test in 『[F2]: System』 → 『4: Application parameter』 → 『4: Sensor synchronization』 → 『2: Environment setting』 → 『Sensor activation = <Normal, Simulation, Test>』