8.17. R211 Servo gun squeeze force setting

8.17. R211 Servo gun squeeze force setting

 

This function is to manually set the pressurizing force when performing the servo gun pressurization.

For details, refer to Hi5 Controller Spot Welding Function Manual

 

(1)   Following screen is displayed if pressing the [R..(NO)] key → [211] → [ENTER(YES)] key.

 

 

(2)   Press the [ENTER (YES)] key after inputting applied pressure to set with the [Number] key.

 

 

 

l  This function cannot be used when Robot operates.

 

l  This can only be set in the spot welding environment. The spot welding item in [F2]: System5: Initialize3: Usage settingmust be set to “Enable”.

 

l  Applied pressure of welding condition file is not changed.

 

l When the set pressurization force is higher or lower than the upper limit value of the current pressurization force table of the servo gun parameter, the following message will be displayed.