8.22. R220Equalizing tip consumption preset

8.22. R220Equalizing tip consumption preset

 

This is function to allow that user can manually set wearing quantity of fixed tip of Equalizer air-pressure gun.

 

(1)   Following screen is displayed if pressing the [R..(NO)] key → [220] → [ENTER(YES)] key.

 

 

(2)   Press the [ENTER (YES)] key after inputting wearing quantity of fixed tip with the [Number] key.

 

 

 

l  This function cannot be used when Robot operates.

 

l  This can only be set in the spot welding environment. The spot welding item in [F2]: System5: Initialize3: Usage settingmust be set to “Enable”.

 

l When the designated type of spot welding gun is “EQ’less”, it is “Enable”. Refer to [F2]: System4: Application parameter1: Spot welding1: Tool No. Corresponding to Gun No., and gun-type set.

 

l  When setting the actual abrasion of the tip higher or lower than the setting, be careful since the pressurization force can be misaligned or it can cause workpiece interference.