Skip to main content

10.4.3.7. SREQ

10.4.3.7. SREQ

 

This function requests the shift amount measured from the external device and saves the shift data to the online shift register after receiving the data.

 

Explanation

Shift amount request 

Grammar

SREQ R=< register num.>,PT=<Port num.> [,<Standby time>,<Exit address>]

Parameter

Register num.

Register in which transmitted shift amount is stored.

1~8

Port num.

RS232C port number to be used for shift amount request and transmission

1~2

Standby time

Standby time until the shift is received

0.0~60.0(sec)

Exit address

Address to exit when the standby time is exceeded

 

Example

SREQ R=1,PT=1

SREQ R=1,PT=1,3,999

 

 

 

l  The received shift amount is saved as the data in online shift register number designated in  [F1]: Service2: Register3: Online shift register.

 

l  When this function is executed, SHIFT  1 CR LF (1: register number) is outputted through RS232C port, and SHIFT X, Y, Z, θX, θY, θZ, CR is inputted from an outside device through RS232C port. Inputted data is stored in 1 register. Transmitted/received data is ASCII code.