10.4.6.8. SensorSync
10.4.6.8. SensorSync
The SensorSync statement determines whether to execute the sensor synchronous operation. When the sensor synchronous operation (Sync=1) is executed, a robot applies the shift as much as the distance that the sensor moves to the rest of the steps until the sensor synchronous operation is off (Sync=0) or the sensor synchronous reset is executed (Sync=2).
Explanation | Sensor synchronous playback | ||
Grammar | SensorSync Sensor=<Synchronization parameter number>,Sync=<Synchronized state> | ||
Parameter | Synchronization parameter number | Synchronization parameter number for the application of the sensor synchronization | 1~2 |
Sync state | 0 : conveyer synchronous operation OFF 1 : conveyer synchronous operation ON 2 : conveyer synchronous operation OFF and conveyer data reset 3 : Completion of the current work | 0~3 | |
Example | SensorSync Sensor=1,Sync=1 |