10.4.6.3. PALRST

10.4.6.3. PALRST

 

The PALRST statement is the function to reset the counter by force during the palletization operation. When the designated input signal is entered, the counter in work is reset to 0. It outputs the response signal and uses the signal as pallet exhaust signal.

 

Explanation

Palletize reset (data input) 

Grammar

PALRST P=<pallet num.>,CS=<cond.signal>, RS=<response signal>

Parameter

pallet num.

Pallet entry number

1~16

cond.signal

Number of a DI input signal to be received from the outside, when palletize is forced to be reset. If the number is 0, the signal is reset unconditionally.

DI range

response signal

Number of a DO output signal to respond to the condition signal, when palletize is forced to be reset.

DO range

Example

PALRST P=1,CS=1,RS=5

 

 

 

l To use this function, the palletizing must be set to <Enable> in [F2]: System5: Initialize3: Usage settingitem.

 

l  Before using this function, always check the data value in [F2]: System4: Application parameter3: Palletizing1: Palletize pattern register. When the setting value is incorrect, the robot may execute unwanted work.