5.1.6. R1-Axis Reduction Gear
5.1.6. R1-Axis Reduction Gear
Attention
Do not inject excessive grease. The excessive grease would cause an abnormal operation. |
n Grease Replenishment
① Remove the grease outlet plug.
② Inject the grease into the grease inlet using a grease gun.
ü Grease type : VIGO GREASE RE0 ü Amount of grease : 200cc(180g) |
Caution
If the specification of the currently filled grease is MOLYWHITE RE100, you must fill the VIGO GREASE RE0 grease after more than 100 hours of operation. |
③ Wipe the outlet port with a cloth and reinstall the inlet/outlet plugs with seal tape
n Grease Replacement
① Remove the grease outlet plug.
② Inject the grease into the grease inlet using a grease gun.
ü Grease type : VIGO GREASE RE0 ü Amount of grease : 435cc(391.5g) |
③ The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color.
④ Wipe the outlet port with a cloth and reinstall the inlet/outlet plugs with seal tape