Skip to main content

5.1.6. R1-Axis Reduction Gear

5.1.6. R1-Axis Reduction Gear​

 

 

Attention

 

Do not inject excessive grease. The excessive grease would cause an abnormal operation.

 

n  Grease Replenishment

 

①    Remove the grease outlet plug.

 

②    Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 200cc(180g)

 

Caution

 

If the specification of the currently filled grease is MOLYWHITE RE100, you must fill the VIGO GREASE RE0 grease after more than 100 hours of operation.

 

③    Wipe the outlet port with a cloth and reinstall the inlet/outlet plugs with seal tape

 

 

n  Grease Replacement

 

①    Remove the grease outlet plug.

 

②    Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 435cc(391.5g)

 

③    The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color.

 