Skip to main content

5.1.6. R1-Axis Reduction Gear

5.1.6. R1-Axis Reduction Gear

 

 

Attention

 

Do not inject excessive grease. The excessive grease would cause an abnormal operation.

 

n  Grease Replenishment

 

    Remove the grease outlet plug.

 

    Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 200cc(180g)

 

Caution

 

If the specification of the currently filled grease is MOLYWHITE RE100, you must fill the VIGO GREASE RE0 grease after more than 100 hours of operation.

 

    Wipe the outlet port with a cloth and reinstall the inlet/outlet plugs with seal tape

 

 

n  Grease Replacement

 

    Remove the grease outlet plug.

 

    Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 435cc(391.5g)

 

    The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color.

 