5.1.5. B-AxisReduction Gear
5.1.5. B-AxisReduction Gear
Attention
Do not inject excessive grease. The excessive grease would cause an abnormal operation. |
n Grease Replenishment
① Prepare a grease nipple A-PT1/8 and then make the R2-Axis 0°degree.
② Remove the grease inlet plug and install grease nipple A-PT1/8.
③ Make the R2-Axis -90°degree and then remove the grease outlet plug.
④ Inject the grease into the grease inlet using a grease gun.
ü Grease type : VIGO GREASE RE0 ü Amount of grease : 250cc(225g) |
Caution
If the specification of the currently filled grease is MOLYWHITE RE00, you must fill the VIGO GREASE RE0 grease after more than 100 hours of operation. |
⑤ Wipe the outlet port with a cloth and reinstall the inlet/outlet plugs with seal tape
n Grease Replacement
① Prepare a grease nipple A-PT1/8 and then make the R2-Axis 0°degree.
② Remove the grease inlet plug and install grease nipple A-PT1/8.
③ Make the R2-Axis -90°degree and then remove the grease outlet plug.
④ Inject the grease into the grease inlet using a grease gun.
ü Grease type : VIGO GREASE RE0 ü Amount of grease : 950cc(855g) |
⑤ The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color.
⑥ Wipe the outlet port with a cloth and reinstall the inlet/outlet plug with seal tape.