Skip to main content

8.36. R361Jog inching level setting

8.36. R361Jog inching level setting

 

Use this to change the inching distance of the currently set level.

 

Table 85 R361 Jog inching level setting

Operation

#1 (Unit)

#2 (Input value range)

R361,#1, #2

0 : Distance

0.001 ~ 1000.00 mm

1 : Angle

0.001 ~ 180.0 deg

 

(1)   Following screen is displayed if pressing the [R..(NO)] key → [361] → [ENTER (YES)] key.

 

 

 

(2)   To set the distance of the currently set jog inching level, enter 0. To set the angle, enter 1 and press the [ENTER (Yes)] key. When 1 (Angle) is entered, the following screen will be displayed.

 

 

 

(3)   Enter the inching angle and press the [ENTER (Yes)] key.

 

 

 

l  This function cannot be executed in AUTO mode.

 

l  Inching distance set by R361 code is set for jog level currently set. Therefore, inching distance is changed equivalent to 8i where current jog level is 8.

 

l  Jog inching operation can only be done when the jog inching key is activated (LED On).

 

l  Because this function is for the engineer, general operator cannot use this function.