10.4.1.13. SELSTN
10.4.1.13. SELSTN
Explanation | Selecting group number for positioner synchronous motion. This function allows independent manipulation of positioners other than selected positioner group by using external signal assigned by the user. | |
Grammar | SELSTN <station number>[,<timeout time>,<shelter address>] | |
Parameter | station | ALL : all positioners are operated. S0 : Each positioner is independently operated. S1~S3 : Selected positioners are operated. |
timeout time | Waiting time until independent operation is completed. | |
shelter addr. | If independent operation is not completed until waiting time is up, positioners are withdrawn to this address. | |
Example | SELSTN S1 → Positioner group 1 is selected. S1 MOVE L,S=300mm/s,A=0,T=0 → Only positioner group 1 is operated. S2 SMOV S1,L,S=100mm/s,A=0,T=0 → Only positioner group 1 is operated. S3 SMOV S1,L,S=100mm/s,A=0,T=0 → Only positioner group 1 is operated S4 MOVE L,S=300mm/s,A=0,T=0 → Only positioner group 1 is operated. S5 SMOV S1,L,S=100mm/s,A=0,T=0 → Only positioner group 1 is operated. SELSTN S2 → Positioner group 2 is selected. S6 MOVE L,S=300mm/s,A=0,T=0 → Only positioner group 1 is operated. S7 SMOV S2,L,S=100mm/s,A=0,T=0 → Only positioner group 1 is operated. S8 MOVE L,S=300mm/s,A=0,T=0 → Only positioner group 1 is operated. S9 SMOV S2,L,S=100mm/s,A=0,T=0 → Only positioner group 1 is operated. SELSTN ALL → All positioner groups are selected. S10 MOVE P,S=100%,A=0,T=0 → All positioner groups are operated. S11 MOVE L,S=1200mm/s,A=0,T=0 → All positioner groups are operated. S12 MOVE L,S=200mm/s,A=0,T=0 → All positioner groups are operated. |
l To select positioner group, set positioner group first.
l Refer to 『Hi5 Controller Positioner Synchronous Function Manual』 for setup and details.