5.1.3. V-Axis Reduction Gear
5.1.3. V-Axis Reduction Gear
Attention
If grease is added without removing the outlet plug, it cause damage to the seal of reducer and grease will go inside the motor and may damage it. It is absolutely necessary to remove the plug. |
n Grease Replacement
① Make the V-Axis Arm horizontal for ground.(V:0°-Floor Type, V:-90°-Shelf Type)
② Remove the grease outlet plug.
③ Inject the grease into the grease inlet using a grease gun.
ü Grease type : VIGO GREASE RE0 ü Amount of grease : 1,600cc(1,440g) |
④ The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color.
⑤ Move the V-Axis for a few minutes to eject the old grease and then add grease until the new grease appears in the outlet port.
⑥ Wipe the outlet port with a cloth and attach the plug with seal tape.