5.1.3. V-Axis Reduction Gear (HS210E)

5.1.3. V-Axis Reduction Gear (HS210E)

 

Figure 5.3 V-axis reducer grease injection/discharge port

 

Attention

 

If grease is added without removing the outlet plug, it cause damage to the seal of reduction gear and grease will go inside the motor and may damage it. It is absolutely necessary to remove the plug.

 

n  Grease Replenishment

 

(1)   Make the V-Axis Arm horizontal for ground.(V:0°-Floor Type, V:-90°-Shelf Type)

 

(2)   Remove the grease inlet plug G1/4 and install grease nipple A-PT1/4

 

(3)   Remove the grease outlet plug G1/4

 

(4)   Inject the grease into the grease inlet using a grease gun

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 2,303cc (2.1kg, for reference)

 

(5)    Inject the new grease until it comes out of the outlet.

The new grease can be identified by color.

 

(6)   Remove the residual grease while moving the V axis for a few minutes, and then inject the new grease until it comes out of the outlet.

 

(7)   Release the over-injected grease and residual pressure (refer to the following removal procedures)

 

(8)   Remove the grease nipple of the inlet and assemble the inlet plug.

 

 

n  Injecting the grease after replacing the reducer

 

(1)    Prepare the grease nipple A-PT1/4 and make the V axis arm in a vertical position (H:90°-Floor Type, H:0°-Shelf Type).

 

(2)   Remove the grease inlet plug G1/4 and fasten the grease nipple A-PT1/4.

 

(3)    Remove the grease outlet plug G1/4.

 

(4)    Inject the grease through the inlet by using the grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 3,070cc (2.8kg)

 

(5)   Inject the new grease until it comes out of the outlet.

 

(6)   Release the over-injected grease and residual pressure (refer to the following removal procedures).

 

(7)   Remove the grease nipple of the inlet and assemble the inlet plug.

 

n  Procedures for replacing the grease and injecting new grease and then removing the over-injected grease and residual pressure

 

(1)   Attach a grease tray or hose to the grease outlet to prevent the surroundings from being contaminated by the discharged grease.

 

(2)   Will operate under the following conditions within the range that will not cause interference with the surroundings.

     Operation angle : 70° or above

     Operation speed : 100%

     Operation time : 20minutes or above

 

(3)   Wipe the outlet with a cloth and assemble the plug as it was.