Skip to main content

10.5.4.4. EGUNSEA

10.5.4.4. EGUNSEA

 

The EGUNSEA statement is the function used to calculate the tip abrasion of the fixed electrode when using the equalizer less air pressure gun.

 

When this command is executed, the gun will move for the designated search distance until the sensor detects a signal. When the sensor detects a signal at a certain location, the location will be used for calculating the abrasion

 

EGUNSEA GN=gun number, SP=search speed, SD= Search distance, DI=DI signal, DT=On/Off

 

Item

Range

Content

GUN

number

1~8

Designate the equalizer less gun number to measure the abrasion

Search

speed

1.0~250mm/s

During the search movement, speed of gun axis is assigned. Search speed by input signal as based on safety speed. Recommended speed is 10mm/sec.

Search distance

1.0~1000.0mm

Designate the maximum gun search distance of the fixed electrode

DI signal

1~256

Designate number for accessing input signal for photo electric tube

On/Off

0~1

Detection condition of signal is assigned.

0 = Detection when Low (Normal High)

1 = Detection when High (Normal Low)

 

 

 

l For the initial use, the tip without abrasion needs to be mounted and the reference location needs to be recorded. This is called gun search reference location recording.

 

l For the gun search reference record, the condition setting/application condition/gun search reference location record need to be shifted to the ON state, before executing the EGUNSEA command. The location detected then will be used as the reference value for measuring the abrasion.