3.3. Example of Applying Teaching
3.3. Example of Applying Teaching
Add the “SEALER ON/OFF” command to the start and end points of the application to apply the sealer as shown below. Adjust the OT or OD parameter for a finer application section adjustment.
S1 MOVE L, S=60%, A=0, T=1 SEALER ON, P=20, F=4 cc/m, OD=10 Application start S2 MOVE L, S=200 mm/s, A=3, T=2 S3 MOVE L, S=200 mm/s, A=3, T=2 SEALER OFF, CRG=1, OD=-30 Filling start S4 MOVE L, S=200 mm/s, A=3, T=2 END
|