Skip to main content

3.3. Example of Applying Teaching

3.3. Example of Applying Teaching

 

Add the “SEALER ON/OFF” command to the start and end points of the application to apply the sealer as shown below. Adjust the OT or OD parameter for a finer application section adjustment.


S1     MOVE L, S=60%, A=0, T=1

       SEALER ON, P=20, F=4 cc/m, OD=10 Application start

S2     MOVE L, S=200 mm/s, A=3, T=2

S3     MOVE L, S=200 mm/s, A=3, T=2

       SEALER OFF, CRG=1, OD=-30 Filling start

S4     MOVE L, S=200 mm/s, A=3, T=2

       END