3.1. Manual Mode Operation
3.1. Manual Mode Operation
Operate the sealer gun booster unit for discharging and filling. Jog the jog key for the booster in a “(-)” direction to discharge the sealer or a “(+)” direction to fill the sealer with the cylinder. When jogging with the “<SHIFT>” key pressed, the motor will work without opening the valves so the cylinder pressure depends on the position. It will help in the inspection of sensor signals and the sealing of valves.
The manual mode does not discharge the sealer solution even with the “SEALER ON” command. However, the pressurization settings will work even in the manual mode if bypass is not enabled. It is important to remember to stop the operation and turn off the motor if the “Enable” key is released without completing the filling or pressurization adjustment.