4. Error and Warning
Code | E6310 | Axis sealer pressurization error too high |
Description | Tolerances of pressure sensor measurement and motor measurement pressure exceeds allowed ranges. | |
Action | 1) Check the sealer pressurization tuning. 2) Check the pressure sensor operation. | |
Code | E6311 | Sealer pressurization too high for filling |
Description | Measured pressure exceeds maximum pressure. | |
Action | 1) Check if the pump pressure is set too high. 2) Check the pressure sensor operation. | |
Code | E6312 | Sealer pressurization too high for waiting for axis |
Description | Sealer pressure exceeds the allowed range. | |
Action | Check the sealing equipment. | |
Code | E6313 | Sealer pressurization too low |
Description | Sealer pressurization is lower than the allowed range. | |
Action | Check for sealer leakage and pressure sensor operation. | |
Code | E6314 | Axis sealer pressurization exceeded maximum value. |
Description | Sealer pressurization exceeds the allowed maximum range. | |
Action | 1) Check if the discharge amount is too high. 2) Check if the viscosity of the sealer solution has increased because of low temperature. 3) Check the discharge valve for opening/closing and the sealing equipment. | |
Code | E6315 | Axis sealer pressure control time out |
Description | Exceeded time to reach target pressurization for sealer. | |
Action | 1) Check the specified value and pressure tuning. 2) Check the valve for opening/closing and any leakage. | |
Code | E6317 | Sealer filling complete time out |
Description | Filling complete condition was not met within the time limit. | |
Action | 1) Check the input valve operation and supply pump pressure. 2) Check the operation of the filling-complete signal or pressure sensor. | |
Code | E6318 | Sealer pressure sensor data error |
Description | Pressure sensor data failed. | |
Action | Check for sensor connection. |
Code | E6319 | Sealing equipment communication error |
Description | There is an error for communication with the sealing equipment. | |
Action | Check for connection with the equipment. | |
Code | E6320 | Sealer valve control signal output unavailable |
Description | The valve control signal cannot be outputted. | |
Action | Stop internal PLC or set SP11 to “On” to run it. | |
Code | E8020 | Jog is not available for the sealer axis. |
Description | The jog function is not available because parameter settings are not complete. | |
Action | Set sealing parameters. | |
Code | E12120 | Sealer commands cannot be executed. |
Description | Sealing condition settings are not complete. | |
Action | Set sealing conditions. | |
Code | E12121 | Sealer gun number setting error |
Description | The sealing gun number setting is not valid. | |
Action | Check the gun number setting and gun allocation signal setting. | |
Code | E18106 | Sealer discharge amount setting is not appropriate. |
Description | The sealer discharge amount setting value is not specified. | |
Action | Set the sealer discharge amount for additional axis settings. |