Skip to main content

4. Error and Warning

 

Code

E6310

Axis sealer pressurization error too high

Description

Tolerances of pressure sensor measurement and motor measurement pressure exceeds allowed ranges.

Action

1) Check the sealer pressurization tuning.

2) Check the pressure sensor operation.

Code

E6311

Sealer pressurization too high for filling

Description

Measured pressure exceeds maximum pressure.

Action

1) Check if the pump pressure is set too high.

2) Check the pressure sensor operation.

Code

E6312

Sealer pressurization too high for waiting for axis

Description

Sealer pressure exceeds the allowed range.

Action

Check the sealing equipment.

Code

E6313

Sealer pressurization too low

Description

Sealer pressurization is lower than the allowed range.

Action

Check for sealer leakage and pressure sensor operation.

Code

E6314

Axis sealer pressurization exceeded maximum value.

Description

Sealer pressurization exceeds the allowed maximum range.

Action

1) Check if the discharge amount is too high.

2) Check if the viscosity of the sealer solution has increased because of low temperature.

3) Check the discharge valve for opening/closing and the sealing equipment.

Code

E6315

Axis sealer pressure control time out

Description

Exceeded time to reach target pressurization for sealer.

Action

1) Check the specified value and pressure tuning.

2) Check the valve for opening/closing and any leakage.

Code

E6317

Sealer filling complete time out

Description

Filling complete condition was not met within the time limit.

Action

1) Check the input valve operation and supply pump pressure.

2) Check the operation of the filling-complete signal or pressure sensor.

Code

E6318

Sealer pressure sensor data error

Description

Pressure sensor data failed.

Action

Check for sensor connection.

 

 

 

Code

E6319

Sealing equipment communication error

Description

There is an error for communication with the sealing equipment.

Action

Check for connection with the equipment.

Code

E6320

Sealer valve control signal output unavailable

Description

The valve control signal cannot be outputted.

Action

Stop internal PLC or set SP11 to “On” to run it.

Code

E8020

Jog is not available for the sealer axis.

Description

The jog function is not available because parameter settings are not complete.

Action

Set sealing parameters.

Code

E12120

Sealer commands cannot be executed.

Description

Sealing condition settings are not complete.

Action

Set sealing conditions.

Code

E12121

Sealer gun number setting error

Description

The sealing gun number setting is not valid.

Action

Check the gun number setting and gun allocation signal setting.

Code

E18106

Sealer discharge amount setting is not appropriate.

Description

The sealer discharge amount setting value is not specified.

Action

Set the sealer discharge amount for additional axis settings.