4.3. Input signal assign
4.3. Input signal assign
The state or motion of the controller can be controlled through the embedded DeviceNet input signal. It is required to assign the input signal number for each remote control item.
(1) Execute 『[F2]: System』 → 『2: Control parameter』 → 『2: Input/Output signal setting』 → 『3: Input signal assign』.
(2) Enter the “.node number.signal number”, and then press the [Enter] button to assign the embedded DeviceNet master input signal.
The picture below shows an example to assign the input signal no. 4 of node no. 3 to the remote mode. Enter .3.4 in the signal input blank, and then press the [Enter] button to input FN3.4 and assign FN3.X4.
Figure 4.10 Embedded DeviceNet master input signal assignment
(3) Enter “object number(5).signal number”, and then press the [Enter] button to assign the embedded DeviceNet slave input signal.
The picture below shows an example to assign the embedded DeviceNet slave input signal no. 4 to the remote mode. Enter 5.4 in the signal input blank, and then press the [Enter] button to input FB5.4 and assign FB5.X4 to the remote mode.
Figure 4.11 Embedded DeviceNet slave input signal assignment