2.4. BD525 status information of the PLC embedded in the robot controller
2.4. BD525 status information of the PLC embedded in the robot controller
Relay | Explanation | Others |
SW330 | BD525 Master: Status of the devices 1) |
|
SW331 | BD525 Master: Count of the set slaves | 0~65535 |
SW332 ~ SW339 | BD525 Master: List of the set slaves | List of bits |
SW340 | BD525 Master: Status of communication (lower 8bit) *2) BD525 Master: Status of the slaves (upper 8Bit) *3) |
|
SW341 | BD525 Master: Count of the active slaves | 0~65535 |
SW342 ~ SW349 | BD525 Master: List of the active slaves | List of bits |
SW350 | BD525 Master: Accumulated count of communication errors | 0~65535 |
SW351 | BD525 Master: Count of the Error slaves | 0~65535 |
SW352 ~ SW359 | BD525 Master: List of the Error slaves | List of bits |
1) BD525 Master: Status of the devices
Bit 0: 1=Ready
Bit 1: 1=Running
Bit 2: 1=Bus On
Bit 3: 1=Configuration locked
Bit 4: 1=New Configuration
Bit 5: 1=Restart required
Bit 6: 1=Restart required Enable
Bit 7~31: Reserved
2) BD525 Master: Status of communication
0=Unknown, 1=NOT Configured, 2=STOP, 3=IDLE, 4=OPERATE
3) BD525 Master: Status of the slaves
0=UNDEFINED, 1=OK(No Fault), 2=FAILED(Errors with one or more slaves)
Table 2‑4 Embedded PLC SW Memory