10.4.5.2. ARCOF
10.4.5.2. ARCOF
ARCOF statement is the command to end the arc welding.
Explanation | End arc welding. This can be used in 4 formats. | ||
Grammar | ARCOF ARCOF ASF# ARCOF AEF#=<Arc end condition number> ARCOF C=<Current output value>,V(VP)=<Voltage output value>,AEF#=<Arc welding end condition number> | ||
Parameter | Arc end condition number | Number of welding condition used when ending arc welding But, if there is current or voltage output in the previous article, the condition set in the previous article is reflected to the current and voltage of the applicable arc welding start condition. | 1~32 |
Current output value | Output current value when ending arc welding | 0~500 | |
Voltage output value (V) Voltage output value (VP) | Output voltage when ending individually set arc welding. Output voltage when ending one source set arc welding | 0.0~40.0 -20~200 | |
Stop time |
| 0.00~10.00 | |
Whether to cancel auto deposition | In case of wire stick after ending arc welding, set whether to use the auto deposition cancel function. | ANTSTK | |
Example | ARCOF ARCOF ASF# ARCOF AEF#=1 ARCOF C=200,V=22,T=1,ANTSTK |
l When the arc welding is set to digital in 『[F2]: System』 → 『5: Initialize』 → 『3: Usage setting』 item, command statement of ‘ARCOF ASF#’ format can only be used.
l When setting the arc welding to analog, all 3 formats excluding the above format can be used.