Skip to main content

11.2. Operation

11.2. Operation

 

The welding data monitoring screen can be selected by accessing [F1]: Service1: Monitoring12: Digital Arc Welding Data.

 

There is another way of selecting the screen. Users need to split the screen by using the [Window adjustment] key on the basic screen first before accessing [F1]: Content sel12: Digital Arc Welding Data.

 

When the monitoring function needs to be run, the ‘Monitoring in detail’ function will be executed basically. It is possible to shift among the monitoring functions by using the [F5] key. The shifting will repeat in the order of ‘Monitoring in detail’ →‘Wave monitoring’→ ‘Wide screen monitoring’ →’ Monitoring in detail’….

 

In order to use the automatic pop-up for the ‘wide screen monitoring’ function, it is needed to access [F2: System]4: Application Parameters2: Arc Welding16: Automatic activation of monitoring during the welding and set it as “Enable”