3.4.3. Accuracy of Installation Surface
3.4.3. Accuracy of Installation Surface
The degree of flatness for the four attachment plate surfaces should satisfy the specification. Use a shim, if necessary. The rest of the surface must be flat within ±2mm.
n Cautions
(1) The flatness of mounting plate must be within 1.0 mm.
(1) Make four plane figures of a sealed plate of 1.0 mm (±0.5 mm) or less.
Figure 3.5 Accuracy of Installation surface