Skip to main content

5.1.4. J4-AxisReduction Gear

5.1.4. J4-AxisReduction Gear

 

 

Attention

Do not inject excessive grease. The excessive grease would cause an abnormal operation.

 

n  Grease Replenishment

 

(1)   Prepare a grease nipple A-PT1/8 and then make the J4-Axis 0°degree.

 

(2)   Remove the grease inlet plug and install grease nipple A-PT1/8.

 

(3)   Make the J4-Axis -90°degree and then remove the grease outlet plug.

 

(4)   Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 250cc

 

(5)   Wipe the outlet port with a cloth and reinstall the inlet/outlet plugs with seal tape

 

Caution

If the specification of the currently filled grease is MOLYWHITE RE00, you must fill the VIGO GREASE RE0 grease after more than 100 hours of operation.

 

n  Grease Replacement

 

(1)   Prepare a grease nipple A-PT1/8 and then make the J4-Axis 0°degree.

 

(2)   Remove the grease inlet plug and install grease nipple A-PT1/8.

 

(3)   Make the J4-Axis -90°degree and then remove the grease outlet plug.

 

(4)   Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 950cc

 

(5)   The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color.

 

(6)   Wipe the outlet port with a cloth and reinstall the inlet/outlet plug with seal tape.