Skip to main content

5.1.6. R1-AxisReduction Gear

5.1.6. R1-AxisReduction Gear

 

 

Attention

There is no grease outlet. Do not inject excessive grease. The excessive grease would cause an abnormal operation.

 

n  Grease Replenishment

 

(1)   Prepare a grease nipple A-PT1/4 and then make the R2-Axis 90°degree.

 

(2)   Remove the grease inlet plug and install grease nipple A-PT1/4.

 

(3)   Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 200cc(180g)

 

(4)   Wipe the outlet port with a cloth and reinstall the inlet/outlet plugs with seal tape

 

Caution

If the specification of the currently filled grease is MOLYWHITE RE00, you must fill the VIGO GREASE RE0 grease after more than 100 hours of operation.