Skip to main content

5.1.2. H-AxisReduction Gear

5.1.2. H-AxisReduction Gear

 

 

Attention

If grease is added without removing the outlet plug, it cause damage to the seal of reducer and grease will go inside the motor and may damage it. It is absolutely necessary to remove the plug.

 

n  Grease Replenishment

 

(1)   Make the H-Axis Arm vertical for ground.(H:90°-Floor Type, H:0°-Shelf Type )

 

(2)   Remove the grease outlet plug.

 

(3)   Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 300cc(270g)

 

(4)   Wipe the outlet port with a cloth and attach the plug with seal tape.

 

Caution

If the specification of the currently filled grease is MOLYWHITE RE00, you must fill the VIGO GREASE RE0 grease after more than 100 hours of operation.

 

n  Grease Replacement

 

(1)   Make the H-Axis Arm vertical for ground.(H:90°-Floor Type, H:0°-Shelf Type )

 

(2)   Remove the grease outlet plug.

 

(3)   Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGO GREASE RE0

ü  Amount of grease : 1,600cc(1,440g)

 

(4)   The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color.

 

(5)   Move the H-Axis for a few minutes to eject the old grease and then add grease until the new grease appears in the outlet port.

 