Skip to main content

5.1.3. R2-Axis Reduction Gear

5.1.3. R2-Axis Reduction Gear

 

 

Attention

 

If grease is added without removing the outlet plug, it cause damage to the seal of reducer and grease will go inside the motor and may damage it. It is absolutely necessary to remove the plug.

 

n Grease Replenishment

 

    Remove the grease outlet plug.

 

    Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGOGREASE RE0

ü  Amount of grease : 50cc

 

Caution

If the specification of the currently filled grease is MOLYWHITE RE00, you must fill the VIGO GREASE RE0 grease after more than 100 hours of operation.

 

    Wipe the outlet port with a cloth and attach the plug with seal tape.

 

 

n Grease Replacement

 

    Remove the grease outlet plug.

 

    Inject the grease into the grease inlet using a grease gun.

 

ü  Grease type : VIGOGREASE RE0

ü  Amount of grease : 240cc

 

    The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color.

 

    Wipe the outlet port with a cloth and attach the plug with seal tape.