Skip to main content

5.1.2. H-Axis Reduction Gear

5.1.2. H-Axis Reduction Gear

 

 

Attention

 

If the grease is injected without removing the plug of the outlet, the grease may cause damage the oil seal, and grease may enter the motor and damage the motor. . Be sure to remove plug.

 

n Grease Replacement

 

(1)   Adjust the posture of H-axis arm vertically.(H:90°- Floor Type, H:0°- Shelf Type)

 

(2)   Remove outlet plug.

 

(3)   Use a grease gun to inject grease through the inlet.

 

ü  Grease type: VIGO GREASE RE0

ü  Amount of grease : 2,889cc / 2.6 Kg

 

(4)    The grease replacement is complete when new grease appears in the outlet port. The new grease can be distinguished from the old one by color..

 

(5)   Discharge excessively fueled grease and residual pressure. (Refer to the discharge procedure below.)

 

(6)   Clean the greased around the outlet and assemble the seal-taped plug into its original state

 

n  Procedure in discharging excessively fueled grease and residual pressure after grease replacement and injection

 

(1)   Attach a grease receiver or a hose to the grease outlet to prevent contamination from discharged grease.

 

(2)   Operate it within a range without surrounding and interference under the following conditions.

    Operation angle : 90° or more

    Operation speed : 100%

    Operation time: 20 minutes or more

 

(3)   Wipe the outlet port with a cloth and attach the plug.

 

 

Attention

 

If the existing injection grease specification is MOLYWHITE RE00, VIGO GREASE RE0 must be injected after over 100 hours.