3.4. Ethernet/IP Communication Format

3.4. Ethernet/IP Communication Format

 

1.   Input Area (Robot Controller to Monitor PLC; PLC Robot Controller)

Classification

Data Description

Remarks

Byte Address

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

0

To check communication

The value of this area is refreshed cyclically from 1 through 5.

1

2

Current value of temperature 1Ch

Monitoring of each channel’s current temperature (in 0.1°C increments)
Ex.: “20.5
°C “205”

3

4

Temperature 2Ch current value display

5

6

Temperature 3Ch current value display

7

8

Temperature 4Ch current value display

9

10

Temperature 5Ch current value display

11

12

Temperature 6Ch current value display

13

14

Temperature 7Ch current value display (reserved)

15

16

Temperature 8Ch current value display (reserved)

17

18

Temperature 1Ch upper limit

Temperature 1Ch lower limit

Temperature 2Ch upper limit

Temperature 2Ch lower limit

Temperature 3Ch upper limit

Temperature 3Ch lower limit

Temperature 4Ch upper limit

Temperature 4Ch lower limit

Monitoring of each temperature channel’s upper/lower temperature limit lamp
True: Alert ON; False: Alert OFF

19

Temperature 5Ch upper limit

Temperature 5Ch lower limit

Temperature 6Ch upper limit

Temperature 6Ch lower limit

Temperature 7Ch upper limit

Temperature 7Ch lower limit

Temperature 8Ch upper limit

Temperature 8Ch lower limit

20

Flow 1Ch current value display

Monitoring of each channel’s current flow (in l/min)
Ex.: “100 l/min”
“100”

21

22

Flow 2Ch current value display (reserved)

23

24

Flow 1Ch upper limit

Flow 1Ch lower limit

Flow 2Ch upper limit

Flow 2Ch lower limit

Not used

Monitoring of each flow channel’s upper/lower flow limit lamp
True: Alert ON; False: Alert OFF

25

Not used

26

Temperature 1Ch upper limit value display

Monitoring of each channel’s upper/lower temperature limit value with the “Byte 1819 temperature alert lamp working (in 0.1°C increments)

Ex.: Upper limit of temperature 1Ch, “30.5
°C “305”

27

28

Temperature 1Ch lower limit value display

29

30

Temperature 2Ch upper limit value display

31

32

Temperature 2Ch lower limit value display

33

34

Temperature 3Ch upper limit value display

35

36

Temperature 3Ch lower limit value display

37

38

Temperature 4Ch upper limit value display

39

40

Temperature 4Ch lower limit value display

41

42

Temperature 5Ch upper limit value display

43

44

Temperature 5Ch lower limit value display

45

46

Temperature 6Ch upper limit value display

47

48

Temperature 6Ch lower limit value display

49

50

Temperature 7Ch upper limit value display (reserved)

51

52

Temperature 7Ch lower limit value display (reserved)

53

54

Temperature 8Ch upper limit value display (reserved)

55

56

Temperature 8Ch lower limit value display (reserved)

57

58

Flow 1Ch upper limit value display

Monitoring of each channel’s upper/lower flow limit value
with the “Byte 28
29” flow alert lamp working (in l/min)

Ex.: Upper limit value of flow 1Ch, “200 l/min”
“200”

59

60

Flow 1Ch lower limit value display

61

62

Flow 2Ch upper limit value display (reserved)

63

64

Flow 2Ch lower limit value display (reserved)

65

66

Quantity of sensors installed

Displays the number of installed sensors.
Ex.: 4 = 4 sensors are installed

67

68

Sensor setting complete

Processing sensor setting

Not used

Light input of current sensor; Mode settings are the same with the sensor settings (output area) from the robot.
Bit 1
True: Sensor setting complete; False: Sensor setting incomplete


Bit 2
True: Processing sensor setting (if incorrect values are written); False: Sensor setting complete

69

Not used

70

Sensor

1Ch output L1

Sensor

2Ch output L2

Sensor

3Ch output R1

Sensor

4Ch output R2

Sensor

5Ch output

Sensor

6Ch output

Sensor

7Ch output

Sensor

8Ch output

Monitoring the output state of each sensor
True: Sensor output ON; False: Sensor output OFF

71

Not used

72

Sensor 1Ch light input display (LGS1)

Monitoring of each sensor’s light input

Display range by sensing mode
H-SP/FAST/STD: 0
4,000;
LONG: 0
8,000;
U-LG/HYPR: 0
9,999

73

74

Sensor 2Ch light input display (LGS2)

75

76

Sensor 3Ch light input display (RGS1)

77

78

Sensor 4Ch light input display (RGS2)

79

80

Sensor 5Ch light input display (reserved)

81

82

Sensor 6Ch light input display (reserved)

83

84

Sensor 7Ch light input display (reserved)

85

86

Sensor 8Ch light input display (reserved)

87

88

Sensor 1Ch setting value display (LGS1)

Monitoring of each sensor’s setting value (threshold)

Display range by sensing mode
H-SP/FAST/STD: 0
4,000;
LONG: 0
8,000;
U-LG/HYPR: 0
9,999

89

90

Sensor 2Ch setting value display (LGS2)

91

92

Sensor 3Ch setting value display (RGS1)

93

94

Sensor 4Ch setting value display (RGS2)

95

96

Sensor 5Ch setting value display (reserved)

97

98

Sensor 6Ch setting value display (reserved)

99

100

Sensor 7Ch setting value display (reserved)

101

102

Sensor 8Ch setting value display (reserved)

103

104

Sensor 1Ch sensing mode display (LGS1)

Monitoring of each sensor’s set sensing mode (response time)

Separation value by sensing mode

1: H-SP (150 us)
2: FAST (500
μs)
4: STD (5 ms)
6: LONG (50 ms)
7: U-LG (100 ms)
8: HYPR (500 ms)

105

106

Sensor 2Ch sensing mode display (LGS2)

107

108

Sensor 3Ch sensing mode display (RGS1)

109

110

Sensor 4Ch sensing mode display (RGS2)

111

112

Sensor 5Ch sensing mode display (reserved)

[Needs to extend the input area for sensor 5Ch or higher]

113

114

Sensor 6Ch sensing mode display (reserved)

[Needs to extend the input area for sensor 6Ch or higher]

115

116

Sensor 7Ch sensing mode display (reserved)

[Needs to extend the input area for sensor 7Ch or higher]

117

118

Sensor 8Ch sensing mode display (reserved)

[Needs to extend the input area for sensor 8Ch or higher]

119

 

2.   Output Area (Robot Controller to Control PLC; Robot Controller PLC)

Classification

Data Description

Remarks

Byte Address

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 7

0

Write flag

Not used

All-channel upper/lower temperature limit value write bit

1

Not used

2

Temperature 1Ch upper limit value input

Set by inputting the upper/lower temperature limit value of each channel

How to set: Input a setting value in the input area of the temperature channel,
and set the write bit to “True.”

Ex.: If “12.3
°C” is set as the upper limit value of temperature 1Ch,
input “12.3” in the temperature 1Ch upper limit value input (“Byte 2
3).
Then, set the all-channel upper/lower limit value write bit (“Bit 1 of Byte 0”) to “True.”

3

4

Temperature 1Ch lower limit value input

5

6

Temperature 2Ch upper limit value input

7

8

Temperature 2Ch lower limit value input

9

10

Temperature 3Ch upper limit value input

11

12

Temperature 3Ch lower limit value input

13

14

Temperature 4Ch upper limit value input

15

16

Temperature 4Ch lower limit value input

17

18

Temperature 5Ch upper limit value input

19

20

Temperature 5Ch lower limit value input

21

22

Temperature 6Ch upper limit value input

23

24

Temperature 6Ch lower limit value input

25

26

Temperature 7Ch upper limit value input (reserved)

27

28

Temperature 7Ch lower limit value input (reserved)

29

30

Temperature 8Ch upper limit value input (reserved)

31

32

Temperature 8Ch lower limit value input (reserved)

33

34

Write flag

Not used

All-channel upper/lower flow limit value write bit

35

Not used

36

Flow 1Ch upper limit value input

Set by inputting the upper/lower flow limit value of each channel

How to set: Input a setting value in the input area of the flow channel,
and set the bit 1 of the upper/lower flow limit write
bit (“Byte 34”) to “True.”

Ex.: If “200 l/min” is set as the upper limit value of flow 1Ch,
input “200” in the flow 1Ch upper limit value input (“Byte 36
37).
Then, set the all-channel upper flow limit value write bit (“Bit 1 of Byte 34”) to “True.”

37

38

Flow 1Ch lower limit value input

39

40

Flow 2Ch upper limit value input (reserved)

41

42

Flow 2Ch lower limit value input (reserved)

43

44

(Reserved)

45

46

(Reserved)

47

48

(Reserved)

49

50

(Reserved)

51

52

Write flag

Not used

Setting value (threshold) for all sensors; sensing mode write bit

53

Not used

54

Sensor 1Ch setting value input (LGS1)

Set by inputting the setting value (threshold) of each sensor

How to set: Input a setting value in the input area of the sensor channel,
and set the bit 1 of the setting value write bit (“Byte 52”) to “True.”

Ex.: If the 1Ch (LGS1) setting value is set to “1234,”
input “1234” in the sensor 1Ch setting value input (“Byte 54
55). Then, set the all-sensor setting value write bit (“Bit 1 of Byte 52”) to “True.”

Input range by sensing mode
H-SP/FAST/STD: 0
4,000;
LONG: 0
8,000;
U-LG/HYPR: 0
9,999

55

56

Sensor 2Ch setting value input (LGS2)

57

58

Sensor 3Ch setting value input (RGS1)

59

60

Sensor 4Ch setting value input (RGS2)

61

62

Sensor 5Ch setting value input (reserved)

63

64

Sensor 6Ch setting value input (reserved)

65

66

Sensor 7Ch setting value input (reserved)

67

68

Sensor 8Ch setting value input (reserved)

69

70

(Reserved)

71

72

Sensor 1Ch sensing mode input (LGS1)

Set by inputting the sensing mode of each sensor

How to set: Input a setting value in the input area of the sensor channel,
and set the bit 1 of the sensing mode write bit (“Byte 52”) to “True.”

Input value of sensing mode
1: H-SP; 2: FAST; 4: STD; 6: LONG; 7: U-LG; 8: HYPR


Ex.: If the sensor 1Ch (LGS1) sensing mode is set to “H-SP,”
input “1” in the sensor 1Ch sensing mode input (“Byte 72
73). Then, set the all-channel sensing mode write bit (“Bit 1 of Byte 52”) to “True.”

73

74

Sensor 2Ch sensing mode input (LGS2)

75

76

Sensor 3Ch sensing mode input (RGS1)

77

78

Sensor 4Ch sensing mode input (RGS2)

79

80

Sensor 5Ch sensing mode input (reserved)

81

82

Sensor 6Ch sensing mode input (reserved)

83

84

Sensor 7Ch sensing mode input (reserved)

85

86

Sensor 8Ch sensing mode input (reserved)

87

88

(Reserved)

89

90

Quantity of temperature sensors installed

Input the quantity of installed temperature sensors


Ex.: 3 channels used
“3”

91

From 92

(Reserved)

Available area in future update

To 119