4.10. Consumption setting
4.10. Consumption setting
The following system variable is used to set the total consumption of the gun or save the total consumption measured through gun search.
Item | Content |
Gun number (1–16) | Designates the welding gun number (up to 16 guns in total) |
When the consumption is arbitrarily set by using the variable above, the total consumption will be applied to the moving or fixed tips based on the consumption ratio set for the moving tip. This value will remain until gun search is performed.
Usage example 1)
V1!=_TIPWEAR[1] The consumption of gun no. 1 measured through gun search will be saved in V1!.
Usage example 2)
_TIPWEAR[2]=V1! The total consumption of gun no. 1 will be saved in V1!.
Caution: This is only applicable for the servo gun and EQless gun. In the case of the EQless gun, the total consumption is the same as that of the fixed tip.