Skip to main content

2.4. Response Time

2.4. Response Time

 

Table22 Measurement of response time(excluding time for detection)

Functions

Response time

STO

78.7us

SLP

149us

SLS

182us

SOS

107us

Fault

1.2ms

The scan-time for all safety functions is 5ms.