Reset All Relays function is the function to initialize the relay values of all the embedded PLCs in HRLadder to “0”.

 

To use this function, the following conditions must be satisfied.

 

(1)   Project file (*.hpp) must be opened and in “ONLINE” status.

 

(2)   Embedded PLC must be turned on and in “STOP”, “remote STOP” or “NO LAD (No ladder file)” condition.

 

Click on the Reset All Relays Tool button on the Tool Bar as shown in [Figure 6.13]. Or select Tool – Clear All Relaysfrom the menu.

 

Figure 6.13 Select Relay Range to Monitor

 

(3)   When you see the following warning message, click on “Yes”.

 

Figure 6.14 Select Relay Range to Monitor

 

(4)   When successful, the following completion message will be displayed.

 

Figure 6.15 Select Relay Range to Monitor