3.4.3. Accuracy of Installation Surface

3.4.3. Accuracy of Installation Surface

 

The degree of flatness for the four attachment plate surfaces should satisfy the specification. Use a shim, if necessary. The rest of the surface must be flat within ±2mm.

 

n  Cautions

 

(1)   The flatness of mounting plate must be within 1.0 mm.

(2)   Make four plane figures of a sealed plate of 1.0 mm (±0.5 mm) or less.

 

 

Figure 3.5 Accuracy of Installation surface