Skip to main content

9.4.3. Gas Spring Technology Data

9.4.3. Gas Spring Technology Data​

 

Table 9‑2 Gas Spring Technology Data

Division

Data

Remark

HS200L

HS260/HH300

Pressure Medium

Nitrogen gas / Hydraulic oil

 

Length of Stroke

200mm

 

Operation Temperature

0 ℃ ~ 80 ℃

 

Gas Volume

0.9 liter

 

Maximum Charging Pressure

140 bar

When the spring surface is 30℃

Optimum Working Pressure

140 bar ~ 125 bar

Maintenance Target Pressure

When the spring surface is 30℃

Minimum Allowable Pressure

105 bar

When the spring surface is 30℃

Weight

About 16 kg

 

 

※   Refer to Table 9-1 Pressure Table by Gas Spring Surface Temperature for the pressure

※   The minimum allowable pressure can vary depending on the load of the robot motor.