3.5.3. Accuracy of Installation Surface
3.5.3. Accuracy of Installation Surface
The degree of flatness for the four attachment plate surfaces should satisfy the specification. Use a shim, if necessary. The rest of the surface must be flat within ±2mm.
n Cautions
① Keep the flatness of the four mounting plates within 1.0 mm.
② The flatness of plate attaching surface must be within 1.0 mm
Figure 3.5 Accuracy of Installation surface