Skip to main content

3. Abnormality and errors

 

Code

There is an error in the property information file.

Contents of abnormality

There is a problem with the stored property information file. Please update the property information through the menu of Data Management → Property Information Importing.

 

 

Code

The value has exceeded the allowable range. [Range]

Contents of abnormality

The input value is exceeding the limited range. Please input a value within the range.

 

 

Code

The number of the original welder is the same as the number of the welder to copy from.

Contents of abnormality

Will be shown when inputting the same welder number for the original welder and the welder to copy from during the process of data copying.

 

 

Code

Class information was not stored correctly.

Contents of abnormality

There is a problem with the class-related information in the property information. Please update the property information through the menu of Data Management → Property Information Importing.

 

 

Code

The error information was not stored correctly.

Contents of abnormality

There is a problem with the error-related information in the property information. Please update the property information through the menu of Data Management → Property Information Importing.

 

 

Code

Data transmission between the main board and teach pendant failed.

Contents of abnormality

Will be shown when an error occurs in the communication system while recording or importing welder data. Please check the connection between the controller and teach pendant.

 

 

Code

The welder is not connected.

Contents of abnormality

The welder of that number is not connected normally through Device Net. Please check the connection.

 

Code

Copying has failed.

Contents of abnormality

Data copying between welders has not completed normally. Please check the network connection of the welders or try copying again.

 

 

Code

There is an error with the welder data file.

Contents of abnormality

There is a problem loading the welder data file. It is required to check whether there is a file and to check the data.

 

 

Code

The property information data is not stored normally

Contents of abnormality

An error occurred while storing the property information file. Please check whether you have enough storage in the teach pendant and then try again.

 

 

Code

Data storing failed.

Contents of abnormality

An error occurred while storing the data. Please check whether you have enough storage in the teach pendant and then try again.

 

 

Code

The version does not match between the welders.

Contents of abnormality

The version does not match between the welders, which to copy from and copy to, making it impossible to perform copying. Please check whether the file changed or the version of the welder changed.

 

 

Code

The waiting time has been exceeded.

Contents of abnormality

Will occur when the communication between the main board and the teach pendant does not work well, or it takes a long time for the controller to process. Please try again.

 

 

Code

The data has an error.

Contents of abnormality

The data of the backup data file has exceeded the normal range.