2.1. Program Reservation Execution Environment Setting
2.1. Program Reservation Execution Environment Setting
Set the reserved execution of programs in [/System/Control Parameters/Program Reserved Execution]
l Apply register number
① Disable – Program Reservation Execution function is not used.
② 20EA
Prepare 20 program reserved execution registers. Error code “E1047” is displayed if more than 20 programs are reserved
③ 1EA
Prepare 1 program reserved execution register. Only 1 program can be reserved. Thus, it cannot be used to make program reservations in situations requiring 2 or more works to be fed consecutively
l Program input type
① External selection
In External Selection - [/System/Control Parameters/Input & Output Signal Setting/Input Signal Assignment], register the inputted program in the program reserved execution register by using the “Program Selection Bit.”
- Assign the program strobe input signal in the picture above
- Assign the Binary/Discrete(OFF->Binary) input signal to select Binary or Discrete reception of an externally inputted program selection signal and use it according to the reception method
- In the reception method, the desired program number is generated after the program selection bit is read according to the Binary/Discrete(OFF->Binary) when the strobe signal is changed from Low to High. The program selection bit input signal must be activated 200 msec before the program strobe input signal
- To use the external selection mode, select “Yes” for “4. Use Program Strobe Signal” in [/System/1. User Environment]
① Internal setting – When the input signal and the applicable program are pre-designated by the user, and the input signal is turned on, the applicable program will be registered to the Program Reservation Execution Register
- A total of 7 different work units are provided
- “Process when Entering Same Program” menu is used only for internal settings
- The input signal of the workbench can be used with the external start and stop buttons. It will be explained in detail in the input signal below
l Equal program input
When scheduling a program number in the program reserved execution register in the “Internal Settings” for the program input method, this function handles the reservation decision if the same program already exists in the register
① Delete - Condition for deleting the program number reserved in the register. It finds and deletes the first number among the identical reserved program numbers in the register. If deletion is executed, “Reserved program (No:xxx) will be deleted.” is displayed on the screen
② Prohibit - Does not register the program if the same program is already reserved in the register. If deletion is executed, “Reserved program (No: xxx) will be deleted.” is displayed on the screen
③ Allow - Puts a program in the register if it is empty
l Start In
① Set the signal for each port of the I/O connector installed on the I/O board
② If the external start and stop signals are not assigned in the Input Signal Assignment, press this input button to use the external start or stop command
- External start : Execute external start simultaneously with program number reservation
- External stop : Execute external stop if currently executing program is reserved
l Start out
① Set the signal for each port of the output connector installed on the I/O board.
② If a lamp is connected to the output signal, the light of the lamp changes as below until the program number is reserved in the register and executed
- If the program number is not reserved, → Lamp is turned off
- If the program number is reserved,→ Lamp blinks
- If the reserved program number is executing, → Lamp is turned on
- If the reserved program number has completed execution,→ Lamp is turned off
l Program
Set the work program of the applicable workstation.
“Reserved program number is not assigned.” is displayed on the screen when a program number has not been assigned