Skip to main content

2.3. BD525 status information of the PLC embedded in the robot controller

2.3. BD525 status information of the PLC embedded in the robot controller​

Relay

Explanation

Others

SW330

BD525 Master: Status of the devices  *1)

 

SW331

BD525 Master: Count of the set slaves

0~65535

SW332

~

SW339

BD525 Master: List of the set slaves

List of bits

SW340

BD525 Master: Communication state(lower 8bit) *2)

BD525 Master: Slave state(upper 8Bit) *3)

 

SW341

BD525 Master: Count of the active slaves

0~65535

SW342

~

SW349

BD525 Master: List of the active slaves

List of bits

SW350

BD525 Master: Accumulated count of communication errors

0~65535

SW351

BD525 Master: Count of the Error slaves

0~65535

SW352

~

SW359

BD525 Master: List of the Error slaves

List of bits

*1) BD525 Master: Status of the devices

Bit 0: 1=Ready

Bit 1: 1=Running

Bit 2: 1=Bus On

Bit 3: 1=Configuration locked

Bit 4: 1=New Configuration

Bit 5: 1=Restart required

Bit 6: 1=Restart required Enable

Bit 7~31: Reserved

 

*2) BD525 Master : Communication state

0=Unknown, 1=NOT Configured, 2=STOP, 3=IDLE, 4=OPERATE

 

*3) BD525 Master : Slave state

0=UNDEFINED, 1=OK(No Fault), 2=FAILED(One or more Slave errors)

 