6.5. Embedded PLC mode
6.5. Embedded PLC mode
This sets the mode to control the Embedded PLC when controlling the input/output signal using the embedded PLC. There are 4 embedded PLC modes totally. Please refer to 『Hi5 Controller Embedded PLC Function Manual』for more details.
Select 『[F7]: Condition setting』 → 『[F1]: App. cnd』 → 『5: Embedded PLC mode』 from the initial screen of manual or auto mode.
n Off
Set the function as disable.
n Stop
This stops the embedded PLC operation. DI, Y, R relay are cleared with the Stop.
n R-Stop (Remote Stop)
This is the remote mode and stops the embedded PLC operation from HRLadder of PC connected to the controller. DI, Y, R relay are cleared with R-Stop
n R-Run (Remote Run)
This is the remote mode and stops the embedded PLC operation from HRLadder of PC connected to the controller.
n Run
The controller operates the PLC program downloaded to controller.
This is enabled only for the monitoring in HRLadder of the PC.
l This function operates only when the dip switch number 5 of the BD510 main board is turned on. When it is turned off, the warning that execution will be impossible will be displayed.