4.2. Step Number Display Window and Step Parameter Display Window
4.2. Step Number Display Window and Step Parameter Display Window
The Step Number display window displays the Step Number currently selected.
A step number is assigned to each teaching point in the Hi5 controller, but a location with an arbitrary name is equivalent to a teaching point in ROBCAD.
The Hi5 OLP package displays locations by assigning a step number to each location based on where a specific location is placed on path. For example, the 5th location of the path will be treated as step 5.
The step parameter display window display displays the current settings of 4 step parameters, including speed, interpolation, accuracy and tools, in a similar format to actual T/P.
Figure 4.4 Step Number display window, Step parameter display window and control unit