5.1. EtherNet/IP I/O mapping

5.1. EtherNet/IP I/O mapping

 

The input and output data of the BD525 EtherNet/IP scanner and adapter will be mapped individually not only to the robot language, but also to the FB1 and FB3 objects of the embedded PLC. There are 960 X inputs and 960 Y outputs. They are accessible through 5 different types as shown in Table 5-1

 

Table 51 EtherNet/IP input and output data

Classification

Command grammar

Size

Description

Remarks

BD525

EtherNet/IP

scanner

Controller output

FB1.Y1~960

960

Bit signal output

 

FB1.YB1~120

120

Byte signal output

FB1.YW1~60

60

Word signal output

FB1.YL1~30

30

Double word signal output

FB1.YF1~30

30

Float signal output

Controller input

FB1.X1~960

960

Bit signal input

 

FB1.XB1~120

120

Byte signal input

FB1.XW1~60

60

Word signal input

FB1.XL1~30

30

Double word signal input

FB1.XF1~30

30

Float signal input

BD525

EtherNet/IP

Adapter

Controller output

FB3.Y1~960

960

Bit signal output

For EtherNet/IP

 

Input

FB3.YB1~120

120

Byte signal output

FB3.YW1~60

60

Word signal output

FB3.YL1~30

30

Double word signal output

FB3.YF1~30

30

Float signal output

Controller input

FB3.X1~960

960

Bit signal input

For

EtherNet/IP

Scanner

 

Output

FB3.XB1~120

120

Byte signal input

FB3.XW1~60

60

Word signal input

FB3.XL1~30

30

Double word signal input

FB3.XF1~30

30

Float signal input