4.2. CC-Link version discrepancy

 

The discrepancy between the version of the CC-Link supported by BD570 or BD58A of the Hi5 controller and the version of the CC-Link set for the CC-Link master of a controller of higher class, such as the process PLC or PC, means that communication will not take place normally.

 

Table 4-2 shows how to identify the discrepancy between the version of the CC-Link of the CC-Link master and the version of the CC-Link of the Hi5 controller.

 

Table 4‑2 CC-Link version discrepancy

CC-Link version

State

Remarks

Master

Hi5

V2.0

V1.0

Master

ERR LED turned on

 

Hi5

Before resetting the master

After resetting the master

V1.0

V2.0

Master

ERR LED turned off

 

Hi5

 

※ The CC-Link communication state of the Hi5 controller can be checked by entering 『[F2]: System』 → 『2: Control parameter』 → 『2: Input/Output signal setting』 → 『11: BD57x fieldbus(CC-Link) information』.