Skip to main content

3.5.3. Accuracy of Installation Surface

3.5.3. Accuracy of Installation Surface

 

The degree of flatness for the four attachment plate surfaces should satisfy the specification. Use a shim, if necessary. The rest of the surface must be flat within ±2mm.

 

n Cautions

 

    The flatness of the 4 mounting plates must be within 1.0 mm.

    The flatness of the 4 areas of the plate for assembly must be within 1.0 mm (±0.5 mm).

 

 

Figure 3.6 Accuracy of Installation surface