Skip to main content

5.2.1. Reducer

5.2.1. Reducer

 

If the reducer is damaged, vibration or abnormal sound will occur. This may cause overloading and an error because of the deviation that interferes with the normal operation and may generate an abnormal sound. As a result, the reducer may not move at all or have a positional deviation.

 

 

n  Investigation method

 

    Investigate whether there is clearance in bearings by applying force to the output axis.

    Investigate whether there is clearance in bearings without a load being applied to the reducer.

    Before any abnormality occurs, investigate whether there is any contact with a peripheral system near the positioner.

 

n  Handling method

 

Replace the reducer. Then, you need facilities, such as a chain block, to hang up the output axis frame. If you have any difficulties, please contact our service department.