5.3. Function execution during stepFWD
5.3. Function execution during stepFWD
This determines whether to execute the function recorded in the job program during step FWD.
This can be set in 3 ways; Off, On and I On for deciding whether to execute the function.
n Off : This only executes the work program end function and ignores all other functions.
n On : This executes all the functions recorded within the work program.
n I On : This only executes the input signal standby function and program end function.
l For step backward movement, all other functions besides the input signal standby function are not executed.