5.1. Error messages
5.1. Error messages
■ Code: | E36000 explosion-proof: Error in the air purging completion sensor |
■ Description: | The sensor signal is not received after the air purging duration. |
■ Action: | Check the air purging completion sensor or the air pressure sensor. |
■ Code: | E36001 explosion-proof: Air pressure low-sensor signal is input. |
■ Description: | The air pressure is low, or there is an error in the low sensor. |
■ Action: | Check the air pressure or the low sensor. |
■ Code: | E36002 explosion-proof: Air pressure high-sensor signal is input. |
■ Description: | The air pressure is high, or there is an error in the high sensor. |
■ Action: | Check the air pressure or the high sensor. |
■ Code: | E36003 explosion-proof: Air pressure high-sensor and low-sensor signals are input. |
■ Description: | There are errors in the two air pressure sensors (low and high). |
■ Action: | Check the two air pressure sensors or the signal lines. |
■ Code: | E36004 explosion-proof: Airflow rate sensor signal is input. |
■ Description: | There is an error in the airflow condition or the sensor. |
■ Action: | Check the air flow condition or the sensor. |
■ Code: | E36005 explosion-proof: The air pressure low-sensor and the airflow rate sensor signals are input. |
■ Description: | There are errors in the air pressure or the two sensors (low, flow rate). |
■ Action: | Check the two air pressure sensors and the signal lines. |
■ Code: | E36006 explosion-proof: The air pressure high-sensor and the air flow rate sensor signals are input. |
■ Description: | There are errors in the air pressure or the two sensors (high, flow rate). |
■ Action: | Check the two air pressure sensors and the signal lines. |
■ Code: | E36007 explosion-proof: Signals from all air pressure sensors are input. |
■ Description: | There is an error in the air pressure sensors. |
■ Action: | Check the air pressure sensors and the signal lines. |
■ Code: | E36020: "G1=" range of the PAINT command has been exceeded. |
■ Description: | The on/off (1/0) range of the PAINT command has been exceeded. |
■ Action: | Enter ON=1 and OFF=0. |
■ Code: | E36021: "ANT=" range of the PAINT command has been exceeded. |
■ Description: | The ANT value range (-60.0–60.0) of the PAINT command has been exceeded. |
■ Action: | Enter a value between -60.0 and 60.0. |
■ Code: | W36000: GUN LED control signal (external input for painting) is off. |
■ Description: | This error occurs when the GUN LED control signal is off. |
■ Action: | Check the GUN LED control signal. |
■ Code: | W36001: No Atom/Spray output signal is assigned for painting. |
■ Description: | This error occurs when no Atom/Spray output signal is assigned for painting. |
■ Action: | Check the setting in “System” → “Application Parameter” → “Painting” → “Output Signal Assignment.” |