5.1. Error Display
5.1. Error Display
If the Hi-LUB is connected to a PLC or others, it emits a signal in case of malfunction. The type of error is shown on the display.
dC | DeviceNet Disconnected |
a) Check the DeviceNet connection. | |
b) Check the Hi-LUB station number. The number is 03. | |
c) Check for any disconnection, and check the wiring. | |
Lo | Low Grease |
a) Check the grease level. | |
b) Replace and refill the grease pouch. | |
* Press the Reset key once after the refilling, and then the alarm will disappear. | |
Em | Empty Grease (Injection will be stopped after the Lo alarm occurs ten times.) |
a) Check the grease level. | |
b) Replace and refill the grease pouch. | |
* Press the Reset key once after the refilling, and then the alarm will disappear. | |
P# | Pressure Alarm (Displays the number of ports that have overpressure) |
a) Check the cause of overpressure. | |
b) Resolve the cause by removing the problematic port hose and tube. | |
* After resolving the problems, press the Run key for operation. |