5.1. PROFINET IO Input & Output Signal Mapping
5.1. PROFINET IO Input & Output Signal Mapping
The input and output data of the BD525 PROFINET IO-Controller and IO-Device will be mapped individually not only to the robot language, but also to the FB1 and FB3 objects of the embedded PLC.
There are 960 X inputs and 960 Y outputs. They are accessible through 5 different types as shown in Table 5-1.
Table 5‑1 PROFINET IO input and output data
Classification | Command grammar | Size | Description | Remarks | |
BD525 PROFINET IO-Controller | Controller output | FB1.Y1~960 | 960 | Bit signal output |
|
FB1.YB1~120 | 120 | Byte signal output | |||
FB1.YW1~60 | 60 | Word signal output | |||
FB1.YL1~30 | 30 | Double word signal output | |||
FB1.YF1~30 | 30 | Float signal output | |||
Controller input | FB1.X1~960 | 960 | Bit signal input |
| |
FB1.XB1~120 | 120 | Byte signal input | |||
FB1.XW1~60 | 60 | Word signal input | |||
FB1.XL1~30 | 30 | Double word signal input | |||
FB1.XF1~30 | 30 | Float signal input | |||
BD525 PROFINET IO-Device | Controller output | FB3.Y1~960 | 960 | Bit signal output |
|
FB3.YB1~120 | 120 | Byte signal output | |||
FB3.YW1~60 | 60 | Word signal output | |||
FB3.YL1~30 | 30 | Double word signal output | |||
FB3.YF1~30 | 30 | Float signal output | |||
Controller input | FB3.X1~960 | 960 | Bit signal input |
| |
FB3.XB1~120 | 120 | Byte signal input | |||
FB3.XW1~60 | 60 | Word signal input | |||
FB3.XL1~30 | 30 | Double word signal input | |||
FB3.XF1~30 | 30 | Float signal input |