4. Error Description

 

Code

E1192

Arc sensing error (Current range exceeded)

Detail

This error occurs when detected welding current exceeds the range. That is, “Abnormal judgment margin” is exceeded for “Abnormal judgment time”.

Action

1. Check welding current detection circuit.

2. For end point, set to “Current abnormal processing method = <End point>”.

3. For non-end point, adjust “Current abnormal judgment margin” and “Current abnormal judgment time”.

 

Code

E1193

Arc sensing error (Current detection too unstable)

Detail

This error occurs when the number of weaving that cannot be fitted to the curve from the detected current value in arc sensing using the curve fitting algorithm exceeds “Permitted cycle exceeding reference value”.

Action

1. Check welding current detection circuit.

2. Adjust the “Bead judgment curve” value slightly higher in – value.

3. Stop location is bead and when the bead detection function is used set to “Bead detection = <Enable>”.

 

Code

E1194

Arc sensing error (Left/Right sensing range exceeded)

Detail

This error occurs when left/right tracking cannot be done for a certain period (5 cycles).

Action

Adjust the current coefficient or maximum calibration distance by sample.

 

Code

E1195

Arc sensing error (Top/Bottom sensing range exceeded)

Detail

This error occurs when left/right tracking cannot be done for a certain period (5 cycles).

Action

Adjust the current coefficient or maximum calibration distance by sample.

 

Code

E1296

Allocate welding current input port

Detail

This occurs when the welding current input port for arc sensing is not set.

Action

Assign the input port for “13: Welding current input port assignment” in arc welding parameter (System > 4: Application parameter > 2: Arc welding).

 

Code

E1295

Arc sensing only supports weaving shape=simple harmonic motion.

Detail

This occurs when the weaving type of weaving condition is not simple harmonic oscillation.

Action

Change the weaving type of weaving condition to simple harmonic oscillation.

 

Code

E1353

Exceeded the permitted trace deviation distance.

Detail

This occurs when the trace deviation distance by tracking exceeded the permitted value.

Action

Edit the teaching location or adjust the permitted trace deviation distance.