Skip to main content

7.5. Daily Inspection

7.5. Daily Inspection

 

Table 73 Daily Inspection

No.

Cycle

(months)

Inspection Part

Inspection Details

Remarks

3

6

12

1

 

Packing of door

Transformed & torn part

 

2

Back side

Dust & rotation in cooling fan wings of heat exchanger

 

Damage & dust in regenerative discharge resistance

 

Check a heating of Transformer Room by touch, and clean the room.

 

Looseness and damage of terminal blocks (TB1, TBAC1)

 

3

Wire harness

Loose & damaged connector

 

4

 

Drive Unit

Loose & damaged connector

 

5

 

Connectors of each board

Check a loose connector by touch

 

6

Operating panel

Check Button switch & LED

 

7

 

Overall Controller

Dust cleaning

 

8

Nameplate

Inspect all kinds of nameplates

 

9

 

Voltage measurement

Primary power voltage

Refer to “6.3.1 Adjustment of Power System”

C2, B2

SMPS (HDI-200)

BKSMPS (CP SNT 250W): Brake power

10

 

Grounding

Check a loose & removed terminal

 

11

 

Battery

Voltage inspection & regular replacement

Main LED

12

Teach Pendant

Exterior inspection, and damage & joint part of connector checking

 

Check LCD Display

 

Check LED Display

 

Check the status of LED and button switch

 

13

Safety related parts

Check emergency stop switching   (operating panel, teach pendant)

 

Check primary power disconnecting switch

  (NFB1)

 

Check enabling device of teach pendant

 

Check circuit protector (CP1)

 

Check magnet connector (MC1, MC2)

 

14

Safety related PCB

Check for BD530 board

  (connector, exterior relay of board)